Wholesale Armored Duplex Single Mode Fiber Factory – SC/APC to SC/APC Simplex OS2 Single Mode Indoor Armored PVC 3.0mm Fiber Optic Patch Cable – RAISE
Wholesale Armored Duplex Single Mode Fiber Factory – SC/APC to SC/APC Simplex OS2 Single Mode Indoor Armored PVC 3.0mm Fiber Optic Patch Cable – RAISE Detail:
Product Description
OS2 9/125 Single Mode SC/APC to SC/APC Simplex Indoor Armored Fiber Optic Cable
Armored fiber optic cable with build-in metal armor can provide stronger protection of the optical fibers than standards fiber optic cables. The rugged armored cables allow optical fiber to be installed in the most hazardous areas, including environments with slight dust, oil, gas, moisture, or even damage-causing rodents and pests.
Product Specification
| Connector Type | SC to SC | Polish Type | APC to APC |
| Fiber Mode | OS2 9/125μm | Fiber Count | Simplex |
| Fiber Grade | G.657.A1 | Minimum Bend Radius | 10D/5D (Dynamic/Static) |
| Cable Diameter | 3.0mm | Cable Jacket
|
PVC(OFNR)/Plenum/LSZH |
| Cable Color | Blue/Orange/Aqua/Yellow/Black | Fiber Cords Structure | Single Armored, Stainless Steel Tube |
| Tensile Loads (Long Term) | 120N | Tensile Loads (Short Term) | 225N |
| Insertion Loss | ≤0.3dB | Return Loss | ≥60dB |
|
Operating Temperature |
-25~70°C | Storage Temperature | -25~70°C |
Product Specification
Product Highlights
Tough Steel Tube Protects Network Connection Further
Stainless steel tube can provide good protection against optical fiber breakage and be used in a slight oil, gas and moisture environment, which ensure the operation of the network.



Meet the Various Indoor Installation Needs
Exceptional durability of armored fiber cables is suitable for network cabinet connection, ceiling channel wiring and under-floor wiring in data center.
Carrier-grade Cable with Guaranteed Quality
Superior cable assemblies reduce light loss during cable bending and easily meet your diverse cabling requirements.

Two Polish Types for Various Signal Sensitivity Demands
The fiber endfaces of UPC and APC result in different signal losses. With an 8° angled endface, APC
is more suitable for high precision fiber optic signal applications.

UPC mainly used for TV, telephony and data systems.

APC mainly used for FTTX, PON and other WDM systems.
Product detail pictures:
Related Product Guide:
"Quality initial, Honesty as base, Sincere support and mutual profit" is our idea, so as to build repeatedly and pursue the excellence for Wholesale Armored Duplex Single Mode Fiber Factory – SC/APC to SC/APC Simplex OS2 Single Mode Indoor Armored PVC 3.0mm Fiber Optic Patch Cable – RAISE , The product will supply to all over the world, such as: Turkmenistan, Jordan, Netherlands, Our company will continue to serve customers with best quality, competitive price and timely delivery & the best payment term! We sincerely welcome friends from all over the world to visit& cooperate with us and enlarge our business. If you are interested in our products, please do not hesitate to contact us, we will be happy to provide you with further information!